Balancing machine, the main performance of the fast balancing machine with the minimum attainable residual unbalance, and unbalance reduction rate of two comprehensive indicators. The former is the minimum value of residual unbalance achieved by the balancing function of the rotor, which is an indicator to measure the higher balance capacity of the balancing machine; The latter is the ratio of the unbalance reduced after a correction to the initial unbalance, which is an indicator to measure the efficiency of balance, generally expressed as a percentage. So, what are the operating steps of the balancing machine? Let's take a look at it.
Place the workpiece - Turn on the host - Press ESC key - Home directory - Select rotor parameters - Select the shape of the graph - Measure the workpiece size (r1,r2,a,b,c,)- Calculate the eccentricity and vibration size - Enter the data of the rotor parameters -ESC- Home directory - calibration - enter the calibration parameters (Calculate the vibration size /r1 or r2*( 3-10 times)-- Measure two pieces of the same weight of the calibration mass with an electronic balance and add it to zero -- start the test (test 3 times)-- retest (remove the weight test 3 times)-- the computer automatically calculates the weight and Angle to be weighted -- find the balance (test the weight on the workpiece according to the parameters suggested by the computer until balance)